The pump was to be modernized. The original is an old centrifugal pump for large-diameter pipelines, and it is no longer made.
We rebuilt the pump in CATIA from its drawings and photos: the spiral casing with the inlet pipe and bolt flange, the impeller and the cover.
Then we checked the model against a 3D scan of the pump in STL format. The last picture shows the scan laid over the CAD model. The model matches within industrial tolerances.