Convert Design Portfolio Knowledge Base Download About
Knowledge Base › STEP › STEP to VDA

Convert STEP to VDA

Solid to surfaces: the shape is kept, the closed volume is not.

Complexity of the conversion: LOW

YesAutomatic conversion (with limits)
YesPriority conversion (automatic, without the free limits)
YesManual work by an engineer

Paid options: if the result does not suit you, we refund the payment.

Order this conversion Reverse: VDA to STEP

STEP and VDA compared

STEPVDA
NameSTEP (ISO 10303)VDA-FS (VDA Surface Interface)
File extension.stp, .step, .stpz.vda
Native programNone (exchange format)None (exchange format)
Binary or textTextText
Polygon meshNo*Not confirmed
NURBS surfacesYesYes**
Solids (B-rep)YesNo***
AssembliesYesNot confirmed
Feature historyNoNo
Textures and materialsNoNot confirmed
AnimationNoNot confirmed
Point cloudNoNo****
DeveloperISO (TC 184/SC 4)VDA (Verband der Automobilindustrie)
Open or proprietaryopen standard (ISO 10303)open standard (German VDA standard; text purchasable)
Free viewerCAD Assistant (Open Cascade, free)
eDrawings Viewer (Dassault Systemes, free)
—

* STEP: The current edition of the standard (AP242) also allows tessellated (mesh) geometry, but such files are rare in practice.

** VDA: Polynomial B-spline curves and surfaces; VDA-FS has no rational geometry.

*** VDA: Rare: only a VDA-FS 2.0 file with complete topology (TOP and FACE entities) can be rebuilt as a solid. Files normally carry surfaces and curves.

**** VDA: VDA-FS can carry point sets, but it is not used for scanned point clouds.

Yes yes   No no   Not confirmed not confirmed by a source yet

What happens to the model

VDA keeps surfaces but not solids. The faces of each STEP solid arrive as separate trimmed surfaces with the same exact shape, but without the information that they enclose a volume. The receiving program has to sew them back into a solid if it needs one, and small gaps may need repair.

Why convert between two exchange formats at all? A CAD program reads every file through its geometric kernel. STEP and IGES are neutral descriptions that each kernel translates in its own way, while some formats are the own files of a kernel: X_T of Parasolid, SAT of ACIS, BREP of Open CASCADE. When a model written by one kernel is read by another, small differences in tolerances can show up as gaps between faces, a solid that falls apart into separate surfaces, or missing faces.

Converting the file into the format of the receiving program's kernel, or rewriting it through another program, often removes such errors. It does not always help: a model that is damaged itself needs repair by an engineer.

Doing it yourself: programs that open STEP and save VDA